Insights
How to benchmark a solar portfolio against P50 and reconcile energy yield reports with actual performance
What P50 and P90 mean, why yield reports and live data diverge, and a monthly routine to reconcile them.
Andreas Lehner, CCO · 2 min read
Published

Fund asset managers get an energy yield assessment for every plant, usually from an independent engineer such as DNV or 3E. Once the plant runs, actual output rarely matches it exactly. This guide explains why, and gives a monthly routine to reconcile the two.
What P50 and P90 mean
P50 is the annual energy the plant is expected to exceed in half of all years. P90 is the level it should exceed in nine years out of ten. Lenders often size debt on P90; investors usually plan on P50.
Why yield reports and live data diverge
- Irradiance: the assessment uses long-term weather; any single month can be sunnier or cloudier.
- Availability: downtime from faults, grid outages or maintenance.
- Degradation: modules lose a little output every year.
- Curtailment: output limited by the grid operator or offtaker.
- Soiling: dust and dirt on modules.
Step 1: Set the expected yield for each site
Take the monthly P50 figures from each yield report and keep them next to the site in your own records.
Step 2: Compare actual against expected every month
Each month, compare actual energy with the expected figure, and look at performance ratio and availability for the same period.
Step 3: Split the gap into causes
Separate shortfalls caused by the weather from shortfalls caused by the plant. A month that was cloudier than average is not a fault. Low availability or a falling performance ratio is.
Step 4: Record the result and update the forecast
Write down the cause of each gap. Over a year, this record shows whether a plant is really underperforming or just had poor weather.
Where AMMP helps
AMMP compares actual against expected yield, and calculates performance ratio and availability the same way across sites and brands. Portfolio benchmarking ranks sites against each other. Ray, the AI coworker, separates resource-driven shortfalls from faults, so your team looks at the right sites first.
Read more: how to calculate performance ratio across a portfolio and why is my solar portfolio underperforming?
Frequently asked questions
What is the difference between P50 and P90?
P50 is the annual energy a plant is expected to exceed in half of all years. P90 is the level it should exceed in nine years out of ten.
Why does my plant produce less than the P50 estimate?
Common reasons are lower irradiance than the long-term average, downtime, degradation, curtailment and soiling. Separate weather-driven shortfalls from plant faults before acting.
Does AMMP import P50 budgets from yield reports?
AMMP compares actual against expected yield and benchmarks sites on performance ratio and availability. Keep your yield report figures in your own records for the comparison.